Electrical & Wiring Diagram

All power supplies are customizable to easily integrate for small, medium and large custom applications utilizing one piece of Smart Film® or multiple pieces operating simultaneously.

  • Engineering time included with all orders
  • Low voltage technology, every project is custom
  • Power inputs of 12-24vdc, 110-120 vac and 220-240vac

Wiring diagram

Basic installation wiring diagram

We supply a complete ready to install system from project scope to completion including engineering time, shop drawings, product, power supplies and trim kits.

Smart Tint basic installation wiring diagram: power controller, junction box, shielded wire, bus-bars, trim kit, edge sealant, dry contact switch and glass controller app
Not to scale. Optional 1/2" conduit. 48-60 VAC to each piece of film. Tap the diagram to open it full size.
  1. Power Transfer Options

    Retractable wire kit, great for sliding doors and movable glass.

  2. Shielded Wire

    16-2 plenum rated/shielded/stranded wire up to 100 feet. Each piece of film has its own dedicated wire.

  3. Bus-bar Trim Kit

    Cover the electrical connections, aka bus bars, with a non conductive trim kit only.

  4. Smart Tint® Power Controller

    110-220VAC source from the breaker box. 48-60 VAC out to the film.

  5. Smart Film® Edge Sealant

    Seal all edges with our Smart Film® Edge Sealant ONLY!

  6. Dry Contact Switch

    Operational doors and double-hung windows.

  7. Bus-Bar

    The electrical connection on each piece of film.

  8. Smart Tint® Glass Controller App

    Optional 3rd party controller, Smart Home System (WIFI): Crestron, Control 4, Lutron, Pro DMX, Savant.

Before you wire

Wiring guidelines

Parallel, never seriesAll film is wired in parallel and NOT in series and NOT daisy chained.
16-2 wire, up to 100 feet16-2 plenum rated/shielded/stranded wire from the transformer to the film.
One wire per pieceEach piece of film has its own dedicated wire.
24 hours to acclimateKeep the film unpowered for a minimum of 24 hours after installation.

Please Note: All power supplies are customizable to easily integrate for small, medium and large custom applications utilizing one piece of Smart Film® or multiple pieces operating simultaneously. We include engineering time with all orders to discuss integration logistics and operational scope of your project prior to finalizing your order. Smart Tint® is a low voltage technology and every project is custom. We recommend all wiring for this technology to be installed by a licensed electrician to ensure that all film is wired in parallel and not in series. You can refer to the diagram above for a point of reference.

It is recommended to use a 16-2 plenum rated/shielded/stranded wire when connecting the film to the transformer up to 100 feet away. Each piece of film should have its own dedicated wire. Multiple pieces of Smart Film® can only have the wiring installed in parallel and NOT in series and NOT daisy chained.

One power supply can control multiple pieces of film simultaneously if desired. This will protect your project from interferences such as LED lighting and other electrical environmental factors that can cause issues with the film’s performance ensuring proper operation at maximum performance.

Please remember to acclimate the film to the installation environment by keeping it in its un powered state for a min of 24 hours post installation after removing the protective liner on the finished side of the technology allowing for any edge sealants to properly dry and accommodate material out gasing. This will provide the best end result.

We will consult with your electrician pre-film installation ONLY to review any questions that they may have in regards to operational scope and project pre wiring. Post Installation consultations / troubleshooting are on a per project basis only and billable.

We have an array of power control units to accommodate for power inputs of 12-24vdc, 110-120 vac, 220-240vac all providing the correct output voltages to the film when installed and wired in accordance with our recommendation. Our systems are third party control compatible and these logistics will be discussed with the engineering time we provide with every order pre installation consultation.

Any post installation questions in regards to your third party control system (Lutron, Crestron, DMX, Arduino, etc.) need to be directed to your electrician or third party integration company. We do not provide support for any 3rd party control systems we simply provide access for them to integrate with our controllers for on/off functionality only. We also offer our own App to control your system as an add-on module. Contact our Sales Team with any questions.

PROFESSIONAL INSTALLATION RECOMMENDED ONLY for the film and all electrical wiring.

Photos and Video of the installation during and post installation are required for any claims of warranty. It is also recommended that a diagram of the finished installation be provided with serial numbers provided for each film location to assist with any troubleshooting and for warranty validation.

Control diagrams

Power control units, wall switches and outlets

Each remote control is dedicated to one power control unit through RF frequency and does NOT need line of sight. Remember to remove the battery cover from the back of the remote control and insert the included 23A 12V battery as shown.

Single power control unit to a non-powered wall switch
Single power control unit to a non-powered wall switchA single power control unit is connected to a non-powered wall switch. The non-powered wall switch controls the on/off functionality of the power control unit.
Cascading power control units to a non-powered wall switch
Cascading power control units to a non-powered wall switchMultiple power control units are connected to a non-powered wall switch. The non-powered wall switch controls the on/off functionality of the power control units.
Power control units to a switchable outlet
Power control units to a switchable outletPower control units are plugged into a switchable outlet and the switchable outlet controls the on/off functionality of the power control units. Same setup for one or multiple units. Output Wires to Wall Switch must be plugged into each Power Control Unit. Then twist the wires and cap with a wire nut as shown to close the circuit.
Electrical connections for nine Smart Tint panels tied to the power control units

H100R diagram: Electrical Connections

  • OUTPUT WIRE connects to the film.
  • WALLSWITCH WIRE can connect to a two pole wallswitch or any third-party controller such as Lutron, Crestron, Limitless Control.
  • There are 9 panels of Smart Tint being utilized in this installation. All pieces of film are tied to the power control units.

Recommended wiring: Use 16-2 plenum-rated, shielded, stranded wire (up to 50 ft). Run in parallel to controller; each film piece requires a dedicated line to prevent interference.

Post-installation: Keep film energized (clear state) for 24–48 hours after removing the protective liner to acclimate to the environment.

Smart Tint Honda application: banks of power supplies wired to conduit and junction boxes
Smart Tint Honda Application
Bottom and top U channel with setting block, 1-5/8 inch by 1-5/8 inch
Bottom and top “U” channel

Power control

Smart Tint power supplies

On/Off only

H15R
On/Off only

Smart Tint Power Supply H15R

Includes remote control and wall switch for on/off only.

The H15R is designed to operate up to 15 square feet (1.5 sq meters) of Smart Tint Switchable Film.

Details and product information
H30R
On/Off only

Smart Tint Power Supply H30R

Includes remote control and wall switch for on/off only.

The H30R is designed to operate up to 30 square feet (3 sq meters) of Smart Tint Switchable Film.

Details and product information
H50R
On/Off only

Smart Tint Power Supply H50R

Includes remote control and wall switch for on/off only.

The H50R is designed to operate up to 50 square feet (5 sq meters) of Smart Tint Switchable Film.

Details and product information
H100R
On/Off only

Smart Tint Power Supply H100R

Includes remote control and wall switch for on/off only.

The H100R is designed to operate up to 100 square feet (10 sq meters) of Smart Tint Switchable Film.

Details and product information
H300R
On/Off only

Smart Tint Power Supply H300R

Includes remote control and wall switch for on/off only.

The H300R is designed to operate up to 300 square feet (30 sq meters) of Smart Tint Switchable Film.

Details and product information
H400R
On/Off only

Smart Tint Power Supply H400R

Includes remote control and wall switch for on/off only.

The H400R is designed to operate up to 400 square feet (40 sq meters) of Smart Tint Switchable Film.

Details and product information

Dimmable, Smart Home compatible

HX100r
Dimmable

Smart Tint Dimmable Power Supply HX100r

Includes remote control and wall switch for on/off and dial knob for dimming.

The HX100r is designed to operate up to 100 square feet (10 sq meters) of Smart Tint Switchable Film.

Details and product information
HX150r
Dimmable

Smart Tint Dimmable Power Supply HX150r

Includes remote control and wall switch for on/off and dial knob for dimming.

The HX150r is designed to operate up to 100 square feet (10 sq meters) of Smart Tint Switchable Film.

Details and product information
HX200r
Dimmable

Smart Tint Dimmable Power Supply HX200r

Includes remote control and wall switch for on/off and dial knob for dimming.

The HX200r is designed to operate up to 200 square feet (20 sq meters) of Smart Tint Switchable Film.

Details and product information

Wiring parts

Switches, cables, trim kits and more

Smart Tint® Trim Kit Tape

Smart Tint® Trim Kit Tape

Adhesive mounting tape for trim kits.

Ask for details
Frameless glass swing doors with Smart Tint film
Frameless Swing Door Wiring
Double Hung Window Contact Switch Installation

Click the link below for Double Hung Window Contact Switch Installation.

Double hung window installation

Notice

For exterior facing windows

Your Smart Tint® installation project is not complete until you seal the electrical bus bar edges with a non-conductive trim kit only. DO NOT PUT ANY SEALANT ON THE ELECTRICAL CONNECTIONS and cover the electrical connections aka “bus bars” with a non conductive trim kit only. Smart Tint is not responsible for any damage occurring from not following our installation guidelines.

If non wired edges are not properly sealed with our Smart Tint® Neutral Cure Acid-Free sealant, water/humidity can access the film and affect the technology making corrosion which causes the film to have streaks/striations and fail as shown in the photo. Wired edges need to be protected with a non-conductive trim to prevent moisture from accessing the film and protect the electrical connection point.

Smart Tint film with streaks and failure along an unsealed edge
Film failure from edges that were not sealed.

Order with confidence

Genuine Smart Tint® is the only ETL-certified Smart Film® in the industry that conforms to UL standards for both United States and Canada!

We are the only company registered with the United States Patent and Trademark Office. All of our Smart Tint® products are manufactured here in the United States, allowing us to offer you our industry leading warranties, fastest turn-around times and practically no manufacturing restrictions. All film is serial numbered to validate authenticity. We offer the largest worldwide network of top installers as well as engineering time for your project with every order.

Aviation | Automotive | Marine | Corporate | Entertainment | Residential | Healthcare | Top Secret

All material is custom cut and pre-wired ready to install.

Please Note: All orders are processed within 24 hours of payment confirmation. After your order has been completed we will provide a set of shop drawings to confirm final measurements and wire locations prior to final manufacturing and shipping.

We do offer an industry leading warranty so please contact us for warranty details on a per project basis.

UL CertifiedETL Listed, IntertekMade in the USA

Let us quote your project today!

Call (866) 249-3077. Thank you and we look forward to working with you! Proudly Made in the USA.

Made in the USAFactory direct pricing
5-year warrantyIndustry leading
ETL certifiedConforms to UL standards
Ships worldwideFastest lead times in the industry
Get my free quote